Specification:
Feature:
Phase sequence detection, live wire inspection, simple power control, live wire identification, phase loss judgment, cable break location detection, DC line detection, and line maintenance.
Non-contact inductive clamp-type measurement, no need to open the wire or touch the exposed high-voltage fire wire. Three super-inductive, high-insulation clamps directly clamp onto the insulation of the three-phase live wire to detect the phase sequence.
Non-contact inspection for safe and fast productivity.
Dynamic sound and light indicate the positive or negative phase of the three-phase power supply, making it clear at a glance.
The base plate of the instrument is equipped with four magnets that can be attached to the metal case of the instrument during testing, making operation convenient and comfortable.
Specification:
Model ETCR1000C
Functions: Phase detection (positive phase, reverse phase, and phase loss), live wire inspection, basic current detection, breakpoint location, and line maintenance.
Power supply: DC 3V, 2 AA alkaline dry batteries, continuous operation for 70 hours.
AC voltage range (V): AC 70-1000V, 40/65Hz (continuous sine wave input).
Terminal wire size: Outer diameter: 1.6-16mm
LED indicator: (Positive Phase Sequence): The four phase sequence lamps light up in sequence (clockwise). (Negative Phase Sequence): The four phase sequence lamps light up in series (counterclockwise). (Live Power): The L1, L2, and L3 lamps light up within the voltage setting range. (Phase Loss): L1, L2, or L3 does not light up. (Short Circuit): L1, L2, or L3 does not light up.
Buzzing: (Positive Phase): The instrument emits intermittent short beeps. (Reverse Phase): The instrument emits a continuous long beep.
Power-on indicator: The indicator light is illuminated when the power is turned on; low power consumption, the battery indicator light is on when the battery is low.
Magnetic force: Four magnets on the back of the meter are attached to the distribution box and can withstand a force of 800 g.
Auto power off: The meter automatically disconnects from the power supply after 5 minutes.
Meter dimensions: Width, height, thickness: 70 mm x 75 mm x 30 mm
Clamp cable length: 0.6 m
Weight: 317 g
Operating temperature and humidity: -10°C–55°C; below 80% RH
Storage temperature and humidity: -20°C–60°C; below 90% rev
Maximum measured voltage AC 1000 V
Dielectric strength 5.4 kVrms
Maximum rated power 100 mVA
Safety devices EN61010-1: 2001, EN61010-031: 2002, Pollution degree 2, CAT 3 (600 V), transient overvoltage 6000 V
Package list:
1 * Non-contact phase tracking detector
1 * User manual
Note: