Ms6818 professional cable tester 12-400V AC/DC metal pipe locator wall underground interruption short circuit detection check
Detection of cables, electrical lines, water/gas supply lines buried in walls or ground
Detection of breaks and short circuits in cables and electrical wires buried in the wall or ground
Detecting fuses and assigning circuits
Detection of interruptions and short circuits in underfloor heating
Detecting sockets and distribution sockets that have been accidentally covered by plastering
Characteristics:
1. The transmitter is integrated with the function of AC/DC voltmeter, which can measure 12 to 400V AC/DC voltage on a linear basis.
2. The transmitter screen can display the preset transmission power, the transmitted codes, the own battery power, the detected mains voltage, the AC/DC status of the detected mains voltage and the mains voltage warning symbol.
3. The transmitter has the function of self-inspection to detect its own working status and display it on the LCD screen for user's reference
4. The receiver sensitivity can be adjusted either manually or automatically
5. The receiver can automatically sweep the frequency, both the transmitter and receiver can work in silent mode
6. Additional transmitters are available to expand or differentiate between multiple signals compactness, durability and portability
Specification:
Model Number: MS6818
Technical specifications:
Voltage measuring range: Transmitter: 12V-400V (AC / DC)
Output signal: Transmitter: 125kHz
Voltage: Transmitter: maximum 400V (AC / DC)
Cable depth measurement: Receiver 0-2.5 m (wall/underground cable)
Main voltage measurement: Receiver 0-0.4m
Environmental specifications:
Working environment: Transmitter: 0~40°c; Receiver: 0~40°c
Stored temperature: Transimiter: -20°c ~ 60°c; Receiver: -20°c ~ 60°c
Relative hamidity (no condensation): Transmitter maximum: 80%; Receiver maximum:
Measuring height: Transmitter maximum: 2000m; Receiver maximum: 2000m
Battery: 6x1.5V aaa battery (not included) 1x9V battery (not included)
Notice
1. This detector can measure when the object to be measured is charged. To avoid electric shock and injury, please provide insulation protection in accordance with occupational safety regulations.
2. When working with a voltage greater than 120v (60v) dc or 50v (25v) eff ac, to prevent electric shock, be sure to comply with the safety regulations for high contact voltage and DIN VDE regulations. The values in brackets apply to restricted areas such as medical facilities, agricultural operations, etc.).
3. When installing or replacing the battery, please pay attention to the correct polarity of the battery. If the battery polarity is reversed, damage to the device may occur.
Package list:
1 x MS6818 Receiver
1 x Transmitter
1 x Test leads (black & red)
1 x test probe (black & red)
1 x crocodile clips (black & red)
1 x Grounding rod
1 x User manualDetail pictures: