We use cookies to improve your online experience. By continuing browsing this website, we assume you agree our use of cookies.
All Products Free Shipping
Your position: Home / Car Diagnose Service Tools / Launch / LAUNCH O2-2 Scopebox

LAUNCH O2-2 Scopebox oscilloscope waveform data analysis Automotive electrical components detection module for X431 PAD VII

Item number: Scopebox
Featuring a new design and upgraded hardware, the LAUNCH O2-2 Scopebox is a versatile and easy to use add-on module that can detects high level faults on various electrical components, such as sensors, acturators and circuits.
Price:
CHF
CHF850.00
CHF1300.00
(35% OFF)
Quantity:
-
+
(2 available)
Shipping Cost:
to
Estimated Delivery Time:
Please select the country you want to ship from
Please select the information you wantX
  • X431 PROS ELITE
  • X-431 PAD VII
  • Description
  • Reviews

The Launch O2-2 Scope Box Oscilloscope is designed to enhance diagnostic accuracy and efficiency in automotive testing. With its advanced features, this oscilloscope captures precise waveforms, making the process up to 70% faster than traditional scopes. It also allows for high-resolution waveform data recording and playback, enabling in-depth analysis. The intuitive virtual keyboard feature further boosts productivity by 90%, streamlining input and settings adjustments.
 

Key Features:

  • 4 Channels with 100MHz Bandwidth: Capture detailed waveforms across multiple channels for comprehensive diagnostics.
  • Auto Configuration: Automatically configures settings, saving you time and effort.
  • One-Click Waveform Save: Easily save and retrieve waveforms with just one click.
  • Cursor Measurement: Perform accurate measurements with customizable cursors.
  • Preset Waveform Parameters: Quickly apply pre-configured waveform settings for consistent testing.
  • Demo Mode: Explore oscilloscope features without requiring actual vehicle connection.
  • Online Help: Access instant support directly through the device.
  • Waveform Math Operations: Conduct complex calculations including addition, subtraction, multiplication, and FFT.
  • 23 Automatic Measurements: View all measurement options on a single screen for easy selection.
 

Enhanced Performance:

  • One-Key Enable Function: Quickly activate essential functions with a single press.
  • 23 Automatic Measurements: Simplify diagnostics with access to 23 automatic measurement options, all viewable on a single screen.
  • 50M Buffer Memory: Store extensive data for detailed waveform analysis.
  • Zoom In/Out Functionality: Precisely examine waveform details with zoom features.
  • Customizable System Settings: Save personalized configurations for future use.
  • Self-Calibration: Ensure maximum measurement accuracy with built-in self-calibration.
  • Comprehensive Automotive Tests: Includes circuits, sensors, actuators, and ignition tests.
  • Multi-Language Interface: User-friendly interface available in multiple languages.
  • USB Data Sync: Easily transfer data to external devices like laptops or tablets.
 

Detailed Product Functions:

  • Vehicle Preset Project Tests: Supports various automotive tests with preset parameters and connection methods.
  • Quick Trigger Source Switching: Effortlessly switch between edge, pulse, and other triggers for precise waveform capture.
  • One-Click Waveform Preset: Save current settings as presets and quickly load them for future tests, enhancing workflow efficiency.
  • Convenient Cursor Operation: Independently control cursors for accurate measurements, improving overall efficiency by over 80%.
  • Adaptive Cursor/Phase Ruler: Cursor and phase ruler scales adjust dynamically with waveform zoom, maintaining consistent measurement ranges.
  • Touch-Sensitive Waveform Zoom: Pinch-to-zoom functionality allows for detailed waveform analysis both horizontally and vertically.
  • Demonstration Mode: Utilize preset sine waveforms to demonstrate oscilloscope functions without needing a live connection.
  • Advanced Math Operations: Perform advanced calculations on waveforms, including addition, subtraction, multiplication, division, and FFT.
 

Connection Guide:

For optimal performance, follow these steps to connect the oscilloscope:

  1. Power Supply: Use the double-clip power cable to connect the oscilloscope to the vehicle battery (red to positive, black to negative). For PADVII series tablets, USB power supply is supported.
  2. USB Connection: Connect the Type B terminal of the USB cable to the oscilloscope and the other end to the diagnostic device's USB interface.

Channels: 4
Bandwidth: 100MHz
Rising Time: 3.5ns (typical)
Accuracy: ±3%
Input Impedance: 1M ±1.5%
Input Type: Single-ended, BNC Connector
Input Coupling: DC, AC
Overload Protection: ±200V on single input
Timebase Ranges: 
1ns~1ks (1 Channel)
1ns~1ks (2 Channels)
1ns~1ks (4 Channels)
Vertical Resolution: 8bits
Buffer Memory: 10M (for 4 Channels)
Power Interface: USB port, DC IN port
Data Exchange Via: USB
Trigger Mode: Normal, Auto and Single SEQ
Advanced Triggers: Edge, Pulse width

 

Package Contents:

  • 1 x Launch O2-2 Main Unit
  • 4 x HT 30 Test Lines
  • 1 x HT25 Secondary Ignition Pick-up Line
  • 1 x Battery Clip Cable
  • 1 x USB Cable
  • 2 x HT201 Attenuators
  • 20 x Piercing Needles
  • 2 Pairs x Multimeter Probes
  • 2 Pairs x Crocodile Clips
  • 5 x Colored 4 Female Probes
  • 4 x Clipper Fuses (5*20mm)
  • 2 x Screw Heads
  • 1 x User Manual
  • 1 x Color Label
  • 1 x Packing List


 
Average rating:
Share your thoughts with other customers
Write a review