introduction
The product is a volumetric infusion pump, features in high safety, simple
operation and long life. Flow control with high accuracy and comprehensive alarm
Measures ensure patient safety and optimal therapeutic effect.
function
1) Flow control with high accuracy ensures optimal therapeutic effect.
2) Be compatible with most standard IV sets.
3) New IV kit provided by user can be calibrated by suppliers, and infusion parameters can be entered into the pump, ensuring accuracy.
4) 2.8'' TFT LCD.
5) work with keys.
6) Remaining infusion time can be displayed during infusion.
7) with reminder function to start the infusion.
8) Alarm for occlusion, air bubble, open door and motor failure, etc.
9) Threshold for pressure alarm can be adjusted by medical staff.
10) Accompanying IV-set clamp prevents liquid from flowing freely when the pump door accidentally opens.
11) A.B.S--ANTI bolus system prevents immediate high dose injection from sudden obstruction
Disappear.
12) Automatically stop during alarm (except "near end", "kvo" and "low battery" alarms).
13) Power supply: AC/DC and built-in Lithium battery.
14) Infusion parameters can be saved after power off.
Performance
◆ Type: volumetric infusion pump
◆ Infusion rate: 1 ~ 699 ml/h, increment: 1 ml/h
◆ Total volume: 1~9999ml, Increment: 1ml
◆ Accuracy: ± 5% (use the iv set calibrated)
◆ Display information: flow rate, total volume, accumulated infusion volume, remaining time
◆ Safety classification: Class i, Type bf applied part
◆ Waterproof degree: ipx2
◆ Working mode: continuous working
◆ Alarm functions: near end, KVO condition, low battery, no power, pressure failure, door failure, air bubble, door open, occlusion, infusion reminder and motor failure.
◆ Air bubble detector: Ultrasound
◆ Tft: 2.8''
◆ Kvo rate: 1 ml/h
◆ Sensitivity for pressure sensor: 1 ~ 3 varieties (it can be adjusted by professional medical staff)
◆ Power supply: AC: 100 ~ 240V, 50/60Hz
Rechargeable Li-Polymer battery, 7.4V/5000mAh
Special security measures:
◆ Accompanying iv-set clamp prevents liquid from flowing freely when the pump door accidentally opens.
◆ High accuracy air bubble detector prevents air bubbles from entering the patient's body.
◆ Pressure sensor prevents occlusion set for iv.
◆ A.b.s system, if the high voltage occlusion appears alarming, stop infusing immediately and remove the pressure of the iv set
Automatically, the immediate high-dose injection prevents the sudden
Disability disappear.
◆ Infusion parameters during infusion are protected against arbitrary changes.
◆ With password protection function (in the system parameter setting and IV set type interface).
Accesories
◆ A power cable
◆ A user manual
Physical property
Dimension: 143.6. mm (l) × 151.8mm (w) × 195.3mm (h)
Weight: approx. 1.9 kg