  • Description
  • Reviews

High Flow Peristaltic Pump WiFi AC100-240V UIP E Stepper Dosing Pump with RS485, Foot Switch for Laboratory and Filling 7.9 x 11.1

 

Features
· Photoelectric sensor added
· Includes a 4.3-inch touch screen for easy operation.
· Rich control methods including touch screen, foot switch, RS485 and analog voltage operation.
· Supports flow rate calibration.
· Supports continuous operation and quantitative mode.
· Supports saving parameters when power off.
· The rear interface has quick-connect terminals, easy to connect.
· Supports remote firmware upgrade.

Specification
Basic Parameters: UIP WIFI E with stepper motor
Power supply: AC100-240V
Flow ml/min: 0.5-1500ml/min
Power (Max.): <50W
Weight: About 3.15kg
Noise: ≤65dB (less than 60dB measured at a distance of 50cm)
Speed ​​range: 0.1-350rpm
Speed ​​adjustment resolution: 0.1rpm
Display mode: LED 4-digit digital tube
Control method: Touch screen, foot switch, external analog (0-5V, 0-10V), 485 communication control
Working mode: Continuous mode, quantitative mode and remote control mode
18# Silicone-200H: 1589ml/min
18# BPT-1000H: 1428ml/min

Description of Working mode
1.Continuous mode:
The pump is applied to non-fixed amounts of added occasions, running the user through the touch screen or foot switch to trigger it. "Select "Switch Mode" in the title bar to enter the mode selection interface, click "continuous" to enter the continuous operation function interface, click the start, the pump runs continuously until the stop button is clicked."After clicking "start", the pump runs continuously until the stop button is clicked;

2.Ration mode:
Suitable for filling occasions, the pump runs for one dosage and then stops automatically. The user can manually trigger the start, you can also set the number of cycles, so that the pump runs cyclically; "Select "Switch Mode" in the title bar to enter the mode selection interface. Click "Ration" to enter the working interface of ration mode.In ration mode, there are two working modes, namely semi-automatic working mode and fully automatic working mode;

Semi-automatic working mode:
After volume adjustment, click the start button to start operation. The volume (flow) displayed on the screen starts counting. When the count value changes from the set value to 0, the pump stops working. Click "Start" again, the pump will run in the above direction again;

Fully automatic working mode:
Set the number of running times, volume, pause time, click to start running, the volume (flow) displayed in the screen starts counting, when the count value from the set value to 0, the pump stops working, at the same time The middle of the screen began to count down the pause time, when counting down to 0, the pump has the work of the pump for each operation automaticallyWhen the pump goes through the set number, the pump stops running and waits for the click to start the next cycle.(Note: Before the pump starts running, the pump tube must first be filled with liquid and air discharged to ensure the accuracy of the pump.)

3.Remote mode:
In remote mode, users can control the running status of the pump through non-touch screen methods, such as RS485, 0~5V/10V analog, suitable for supporting user systems;"Select in the title bar "Switch mode" to enter the mode selection interface, and click "Remote control" to enter the remote control interface.

4.Analog control:

In the application scenario that requires the use of analog control equipment, you can choose analog control to achieve motor speed control. The value of the analog determines the running speed of the motor.Analog has two options: current or voltage, of which the current mode can be adjusted according to needs;According to the definition of the analog interface, select the analog communication line (the following figure), select the corresponding analog in the remote control interface, and click to enter the corresponding analog control interface.

Each interface definition
1 RS485 A RS485 data+
2 RS485 B RS485 data-
3 0-5V/10V+ voltage analog quantity positive
4 0-5V/10V – analog voltage quantity negative
5 OUT PUT 24V 5mA digital output
6 DIR: Digital direction control, supports dry contact signal (NPN).
7 Foot switch: Foot switch, digital input, supports dry contact signal (NPN), active signal (PNP).
8 GND digital

Packing list
1× UIP WIFI E;
1× Power cable;
1× Foot switch;
1× Smart