Patient monitor for human use cms1000
Accessories
1) Adult fingertip spo2 probe
2) Adult nibp cuff
3) nibp extension tube
4) ECG cable
5) ECG electrode
6) Temperature probe
7) Power cord
8) User manual
Veterinary patient monitor cms1000vet
Accessories
1) spo2 probe extension cable
2) Veterinarian fingertip spo2 probe
3) Veterinarian nibp cuff
4) nibp extension tube
5) ECG cable
6) ECG electrode
7) Temperature probe
8) Power cord
9) User manual
Introduction
The monitor has abundant functions which can be used to monitor adults, children and neonates. It is powered by 100V-240V~50Hz/60Hz. Users can select different parameter configurations according to requirements. It displays real-time data and waveform through 5'' color TFT LCD. It can be connected to a central monitoring system via a wireless network to form a network monitoring system.
It can monitor such parameters as ECG, RESP, SPO2, PR, NIBP, TEMP and CO2 (optional). It integrates parameter measurement module and display into one device to form a compact and portable monitor.
Function
Parameters: ECG, RESP, SPO2, PR, NIBP, TEMP, CO2 (optional)
1) ECGHeart rate (HR)
ECG waveform
2) Respiratory rate (RR)
Respiratory waveform
3) SPO2Oxygen saturation (SPO2)
Plethysmogram (Pleth) waveform
Pulse rate (PR)
Bar graph
4) NIBPPsychstolic pressure (SYS), Diastolic pressure (DIA), Mean pressure (Average)
5) TEMP
6) CO2 (optional) ETCo2, INSCO2, AWRR
It has abundant functions, such as audible and visual alarm, trend data storage and output, NIBP measurement, alarm event marking and drug concentration calculation.
Features
1)5'' color TFT LCD, multi-language interface (Simplified Chinese, English, Russian, Kazakh, Slovak, Czech, Spanish, etc.).
2)Fanless design, quiet, energy saving and clean, which reduces the possibility of cross infection.
3)With standard interface, OxyCRG, large character interface and full lead interface, convenient to observe.
4)Waveform, parameter color and location can be set optionally.
5)All operations can be completed by the buttons and touch screen.
6)Adopt digital SPO2 technology, anti-motion and anti-ambient light interference, and measurement can be carried out under the circumstance of low perfusion.
7)NIBP measurement mode: manual/auto/stat, memory for 2400-group NIBP data.
8)Connection to central monitoring system by WiFi.
9) Built-in large capacity battery, meets the requirements of long-term operation. AC/DC, achieves uninterrupted monitoring.
10)Anti-high frequency surgical unit, defibrillation safe (special leads are necessary).
Performance
▲ Ecg
Lead Mode: 3-Lead: i, ii, iii
5-Lead: i, ii, iii, avr, avl, avf, v
Waveform: 3-Lead, 1 channel
5-Lead, 2-Channel
Gain: 2.5mm/mv, 5.0mm/mv, 10mm/mv, 20mm/mv
Scan Speed: 12.5mm/s, 25mm/s, 50mm/s
Hr
Measurement and Alarm Range:
Adult: 15~300bpm
Pediatric/Neonatal: 15~350bpm
Accuracy: ±1% or ±1bpm, whichever is greater
Resolution: 1bpm
▲ Resp
Method: R-F (RA-LL) Impedance
Respiratory rate:
Measurement and alarm range: 0 ~ 150 rpm
Resolution: 1 rpm
Accuracy:
7 rpm ~ 150 rpm, ± 2 rpm or ± 2%, whichever is greater;
0 rpm ~ 6 rpm, not specified
Apnea alarm: 10 ~ 40 s
Scan speed: 12.5mm/s, 25 mm/s
▲ Nibp
Measurement mode: Oscillometry
Working mode: manual/auto/stat
Measurement interval in auto mode: 1 / 2 /3 / 4 / 5/ 10 / 15 / 30 / 60 / 90 / 120 / 180 / 240 / 480 minutes
Measurement period in stat mode: 5 minutes
Measurement and alarm range: 0 ~ 300 mmhg
Resolution: 1 mmhg
Cuff pressure accuracy: ± 3 mmhg
Measurement accuracy:
Maximum mean deviation: ± 5 mmhg
Maximum standard deviation: 8 mmhg
Overpressure protection:
Adult: 297 ± 3 mmhg
Pediatric: 260 ± 3 mmhg
Neonatal: 147 ± 3 mmhg
▲ Spo2
Measurement and alarm range: 0 ~ 100%
Resolution: 1%
Accuracy: 70% ~ 100%: ± 2%;
0% ~ 69%: not specified
▲ Pr
Measurement and alarm range: 25 ~ 250 bpm
Accuracy: ± 2 bpm or ± 2%, whichever is greater
▲ Temp
Measurement and alarm range: 0 ~ 50 ℃
Resolution: 0.1 ℃
Accuracy: ± 0.1 ℃
▲ Co2 (optional)
Measurement mode: mainstream or side stream
Measurement range: 0 ~ 150 mmhg
Resolution:
0.1 mmhg: 0 ~ 69 mmhg
0.25 mmhg: 70 ~ 150 mmhg
Accuracy:
0 ~ 40 mmhg: ± 2 mmhg
41 ~ 70 mmhg: ± 5%
71 ~ 100 mmhg: ± 8%
101 ~ 150 mmhg: ± 10%
Awrr measuring range:
Side stream: 2 ~ 120 rpm
Mainstream: 2 ~ 150 rpm
Accuracy: ± 1 rpm
Apnea alarm: yes
▲ Power supply: 100 V-240 V ~ 50 Hz/60 Hz
▲ Safety class: Class II